Type code
• ABB ACS350 General Machinery Drives
• Technical Specifications
• Ratings, Types, Voltages and Construction Notes for Product Selection 240VAC
• Ratings (prices) 80VAC Ratings
• Dimensions, Weight and Noise
• Interface and Options (prices)
• Technical Data
• Control Connections
Ratings, types, voltages and construction
Voltages
The ACS350 is available in two voltage ranges: 2 = 200 240 V 4 = 380 480 V
Construction
01U or the 03U within the type code indicates the number of input phases for the power and EMC filtering. 01 = 1-phase (200 240V only)
• 03 = 3-phase (200 240V and 380 480V)
• U = EMC filter disconnected, 60 Hz frequency
• (In case the filter is required it can easily be connected.)
Notes for Product Selection
General Notes
• 2N: continuous base current at 400C (104F) and 500CC (1200CF). Overload cycle 150% for 1 minute / 10 minutes allowed.
• Continuous output current at 5O0CC (1200C ) shown for 230Vac NEC motor ratings. When used at 500CC (1200C) at input voltages less than 230Vac may require larger drive.
• Current ratings do not change with different supply voltages.
• The rated current of the ACS350 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
• Horsepower ratings are based on NEC motor ratings for typical 4-pole motors (1800 rpm). Check motor nameplate current for compatibility.
240Vac Ratings (pricing
3-phase supply voltage 208, 230 or 240 V. The power ratings are valid at nominal voltage, 208Vac at 400C (1040F) or 230Vac at 500C (1200CF).
Type Code |
Nominal ratings |
||||
400C (1040F) Continuous Rating | 500C (1200F) Continuous Rating | Frame Size | |||
I2N A | PNHP | I2NA | PNHP | ||
1-Phase Un = 200040V (200, 208, 230, 240V) | |||||
ACS350-01U-02A4-2+J404 |
2.4
|
0.5
|
2.2 |
0.50 |
R0 |
ACS350-01U-04A7-2+J404 |
4.7 |
1 |
4.2 |
1.0 |
R1 |
ACS350-01U-06A7-2+J404 |
6.7 |
1.5 |
6.0 |
1.5 |
R1 |
ACS350-01U-07A5-2+J404 |
7.5 |
2 |
6.8 |
2 |
R2 |
ACS350-01U-09A8-2+J404 |
9.8 |
3 |
8.8 |
2 |
R2 |
3-Phase Un = 2000240V (200, 208, 230, 240V) |
|||||
ACS350-03U-02A4-2+J404 | 2.4 | 0.50 | 2.2 | 0.50 | R0 |
ACS350-03U-03A5-2+J404 | 3.5 | 0.75 | 3.2 | 0.75 | R0 |
ACS350-03U-04A7-2+J404 | 4.7 | 1 | 4.2 | 1 | R1 |
ACS350-03U-06A7-2+J404 | 6.7 | 1.5 | 6.0 | 1.5 | R1 |
ACS350-03U-07A5-2+J404 | 7.5 | 2 | 6.8 | 2 | R1 |
ACS350-03U-09A8-2+J404 | 9.8 | 3 | 8.8 | 2 | R2 |
ACS350-03U-17A6-2+J404 | 17.6 | 5 | 15.8 | 5 | R2 |
• Mumbai, Maharashtra | • Hubli |
• Pune, Maharashtra | • Coimbatore |
• Ahmadabad ,Gujarat | • Delhi / New Delhi |
• Vapi | • Chhotanagpur |
• Surat | • Kolkata |
• Vadodara | • Ahmedabad |
• Chennai | • Bengaluru |
• Vishakhapatnam | • Bhopal |
• Kollam | • Bhubaneswar |
• Chandigarh | • Coimbatore |
• Gurgaon | • Hyderabad |
• Jaipur | • Jamshedpur |
• Kharghar | • Kolkata |
• Lucknow | • Kochi |
• Nagpur | • Navi Mumbai |
• New Delhi | • Puducherry |
• Vadodara | • Visakhapatnam |
• Dubai | • Mecca |
• Abu Dhabi | • Medina |
• Oman | • Dhaka |
• Kuwait | • Seeb |
• Bahrain | • Salalah in Oman |
• Qatar | • Astana |
• Saudi Arabia | • Almaty in Kazakhstan |
• Nigeria | • Mogadishu |
• Syria | • KhartoumOmdurman |
• Tashkent | • Dar es Salaam |
• Jeddah | • Alexandria |
• Accra | • Nairobi |
• Kano | • Algiers |
• Addis Ababa | • Luanda |
• Dakar | • Tripoli |
• UAE | • Harare |
• Douala | • Hargeisa |
• Brazil | • Jakarta |
• Iran | • Khartoumomdurman |